On engineering drawings, H7/h6 looks like a straightforward, universally defined ISO fit. But on the production floor in Zhejiang manufacturing facilities, what the tolerance stack says on paper and what actually happens when you slide a metal shaft into a plastic bore—or two machined hardware parts together—often reveals gaps that cause assembly delays, rework, and unplanned costs. As a manufacturer focused on injection molding and hardware production, we’ve seen even experienced engineering teams overlook material-specific behavior or process variation when specifying this common close clearance fit, leading to avoidable project setbacks.
What Is H7/h6 Fit, Exactly?
H7/h6 is a standard close clearance fit defined in the ISO 286 tolerance system, one of the most widely used fit specifications for industrial components worldwide. It falls under the category of clearance fits, meaning there is always a small intentional gap between the mating hole and shaft when parts are at the standard reference temperature of 20°C.

To break down the notation simply:
- H7 refers to the tolerance of the hole component. The “H” indicates a hole-basis fit (where the hole is the reference part with its lower deviation at zero), and “7” denotes the IT7 tolerance grade, a mid-level precision grade suitable for most general industrial applications.
- h6 refers to the tolerance of the shaft component. The lowercase “h” matches the hole-basis system with its upper deviation at zero, and “6” denotes the IT6 tolerance grade, slightly tighter than the hole’s IT7 grade to ensure consistent clearance across the full tolerance range.
Unlike transition or interference fits, H7/h6 does not require force, heat, or press tools for assembly. Parts slide together smoothly, maintain accurate alignment, and can be disassembled and reassembled repeatedly without wear or damage when produced to spec.
How Tolerance Values Scale With Nominal Size
It’s important to note that exact H7/h6 tolerance values change with the nominal size of the mating parts, as IT grades are proportional to part dimensions. For example, for a nominal 10mm diameter:
- The H7 hole has a tolerance range of 0 to +0.015mm
- The h6 shaft has a tolerance range of -0.009mm to 0
- The minimum clearance is 0mm, and maximum clearance is 0.024mm
For a 50mm nominal diameter, the ranges expand: H7 is 0 to +0.025mm, h6 is -0.016mm to 0, with maximum clearance of 0.041mm. Always reference the latest ISO 286 tables for your specific nominal size to avoid calculation errors.

Where H7/h6 Close Clearance Fit Is (and Isn’t) the Right Choice
One of the most common mistakes we see in incoming OEM/ODM drawings is specifying H7/h6 for every close-fit application, even when the use case calls for a tighter or looser fit. For general plastic components, tool accessories, and standard hardware parts, H7/h6 is ideal for the following scenarios:
- Sliding or moving components that require precise alignment with minimal play, such as tool guide pins, adjustable fixture parts, or sliding hardware mechanisms
- Interchangeable spare parts where consistent fit across production batches is critical for field replacement
- Assembly jigs and tooling components that need repeatable positioning and frequent disassembly
- Low-friction rotating parts for light-duty applications where tight radial play is required but no press fit is needed
H7/h6 is not the right choice for applications where parts need to be permanently fixed together (use an interference fit instead), or where loose, easy assembly is more important than precise alignment (use a looser clearance fit like H8/f7). It also requires careful adjustment when applied to plastic injection molded parts, which we cover in more detail later.
The Spec vs. Shop Floor Gap: Common H7/h6 Fit Failures
On paper, H7/h6 is a clear standard. In real production, however, three issues account for the majority of fit-related quality problems we encounter across injection molding and hardware projects:
1. Applying Metal Tolerance Logic Directly to Plastic Parts
This is the single most common error for buyers specifying H7/h6 for plastic components. ISO fit grades were originally developed for metal parts, and plastic materials behave very differently: they shrink after molding, expand more with temperature changes, and can creep under load over time.
For example, a customer once sent a drawing for a 30% glass-filled nylon tool handle with an H7 bore intended to mate with a h6 steel shaft. The customer assumed the standard H7 tolerance would apply, but did not account for the 0.3% transverse shrinkage rate of the glass-filled resin. After molding, the bore was 0.04mm smaller than the nominal H7 lower limit, resulting in a transition fit that required manual reaming for 15% of production parts. The fix was simple: adjust the mold cavity size to compensate for shrinkage, but this required a two-week mold revision that delayed the project.
2. Ignoring Form and Surface Finish Deviations
Many quality teams only check single-point diameter measurements for H7/h6 parts, but form deviations like ovality, taper, or surface roughness can make a part that meets diameter specs fail assembly fit tests. For example, a turned metal shaft with a 0.8Ra surface finish will slide into an H7 bore much more easily than a shaft with a 3.2Ra finish, even if both are within h6 diameter tolerance.
3. Unclear Fit Basis on Drawings
We occasionally receive drawings that only note “H7/h6 fit” without specifying whether it is hole-basis or shaft-basis, or which part is the reference. For small production runs, this can lead to mismatched tolerances if the manufacturing team assumes the wrong basis, resulting in parts that do not fit as intended.
H7/h6 Fit Quality Control Checklist for Buyers and Engineers
To avoid the common issues outlined above, we recommend using this simple checklist at the start of any project that requires H7/h6 fits, and again during first-article inspection:
- Confirm the fit is explicitly defined as ISO 286 hole-basis H7/h6 on your drawing, with clear callouts for which part is the hole (H7) and which is the shaft (h6)
- For plastic injection molded parts, share the full resin specification (grade, filler content, expected shrinkage rate) with your manufacturer so they can adjust mold dimensions to hit the target tolerance after shrinkage
- Specify the reference temperature (20°C is standard for ISO fits) for inspection, especially for parts with large dimensions or materials with high thermal expansion coefficients
- Require first-article inspection to include multi-point diameter measurements (at least 3 cross-sections per bore/shaft) to check for ovality, taper, or other form deviations
- Add a physical assembly fit test to your acceptance criteria, using matched production parts, rather than relying solely on individual dimension measurements
- For high-volume projects, agree on a sampling plan for fit testing during mass production to catch process drift early
H7/h6 Fit Considerations by Part Type (Sourcing Decision Table)
The manufacturing approach and risk profile for H7/h6 fit parts varies significantly depending on whether you are sourcing plastic injection molded parts, machined metal hardware, or tool accessories. The table below summarizes key factors to discuss with your manufacturer before production starts:
| Part Type | Primary Tolerance Risk | Recommended Validation Step | Cost Impact Note |
|---|---|---|---|
| Plastic injection molded components | Resin shrinkage, warpage, and thermal expansion causing deviation from target H7/h6 dimensions | Run a 10-20 piece prototype sample from production-grade resin, test fit with mating parts, and adjust mold cavities before mass production | Mold adjustments for tight tolerances add 10-20% to initial tooling cost, but reduce post-production rework costs by 30-50% on average |
| Machined metal hardware parts | Form deviations (ovality, taper) from machining process drift, or surface finish issues affecting assembly feel | Include form tolerance callouts (circularity, straightness) on drawings, and verify with CMM inspection for first articles | IT6/IT7 grade tolerances are achievable with standard CNC machining, so no significant cost premium applies for most standard metal materials |
| Tool accessories and assembly components | Tolerance stack-up in multi-part assemblies leading to fit issues even if individual parts meet spec | Conduct a full assembly fit test with all mating components at first article stage, under expected use temperature conditions | Early fit testing adds 1-3 days to prototype lead time, but avoids costly full production rework and delivery delays |
These are general guidelines, of course. Exact costs and lead times will depend on part size, complexity, material, and order volume.
Best Practices for Collaborating With Chinese Manufacturers on H7/h6 Fit Projects
After two decades of supporting global OEM/ODM customers with H7/h6 fit parts from our Zhejiang facility, we’ve found that clear, upfront communication eliminates 90% of fit-related quality issues. Here are our top recommendations for procurement and engineering teams:
- Don’t rely on generic “close fit” notes. Explicitly write “ISO 286 H7/h6 hole-basis fit” on your drawing, with tolerance values called out for reference if possible. This removes ambiguity for both engineering and quality teams on the manufacturing side.
- Share your use case, not just your drawing. If the part will operate at high or low temperatures, be subject to repeated assembly/disassembly, or need to hold tight alignment under load, share those details. Your manufacturer can recommend small adjustments (like slightly looser clearance for high-temperature plastic parts) that improve performance without changing the fit grade.
- Agree on inspection methods upfront. Different measurement tools (vernier caliper, micrometer, CMM, bore gauge) have different accuracy levels. Confirm which tools will be used for H7/h6 fit inspection, and what the acceptance criteria are, to avoid disputes later.
- For plastic parts, prioritize mold trial samples over 3D printed prototypes. 3D printed prototypes do not replicate the shrinkage and material properties of injection molded parts, so fit test results from 3D prints will not reflect mass production performance. Always test fit with actual injection molded samples from the production mold before final approval.
Final Thoughts
H7/h6 is one of the most versatile and widely used ISO fit standards for general industrial components, but its successful implementation depends on far more than just copying a tolerance callout onto a drawing. Whether you are sourcing plastic injection molded parts, machined hardware, or tool accessories, the key to consistent, cost-effective H7/h6 fit performance is aligning on material behavior, process capabilities, and inspection criteria with your manufacturing partner early in the project.
At the end of the day, a fit that works on paper but fails on the assembly line adds no value to your project. Taking the time to validate fit with real production parts, and accounting for material and process variables upfront, will save you time, cost, and frustration over the life of your project.